Coaxial Cable

Broadband/MATV - 75Ω

RG-6 Plenum

Broadband - RG-6 Plenum
Approvals:

Applications:

Temperature:

Conductor:


Insulation:

Shield:


Jacket:
UL Type CP

75Ω Broadband/MATVP, CATVP

0°C to 75°C

Annealed Solid Bare Copper
or Copper Clad Steel

Gas Injected Foam FEP

Aluminum or Tinned Copper Braid
Aluminum Mylar Foil

Plenum Natural PVC, PVDF, or SGPVC

Cross Section

Specifications
Part Number Conductor
(Type, DCR)
Dielectric Type
Nominal O.D.
V.P.
Shield Type
Coverage
Nominal D.C.R.
Jacket
(Type, Thickness)
Jacket O.D. Nominal Capacitance
Weight (lbs)
Per Mft.
pF/ft pF/m
IP181CV4
Non (UL)
18 AWG
Solid CCS
31.93 Ω/MFT
101.70 Ω/km
Gas Injected Foam FEP
.170"
83%
AL Foil
40% AL Braid
14.9 Ω/MFT
48.9 Ω/km
PVDF
.020"
.244" 16.2 53.1 35
IP181CV6 18 AWG
Solid CCS
31.93 Ω/MFT
101.70 Ω/km
Gas Injected Foam FEP
.170"
83%
AL Foil
60% AL Braid
9.7 Ω/MFT
31.8 Ω/km
PVDF
.020"
.244" 16.2 53.1 32
IP181CV9 18 AWG
Solid CCS
31.93 Ω/MFT
101.70 Ω/km
Gas Injected Foam FEP
.170"
83%
AL Foil
90% AL Braid
7.0 Ω/MFT
23.0 Ω/km
PVDF
.020"
.244" 16.2 53.1 38
IP182CV6 (2) 18 AWG
Solid CCS
31.93 Ω/MFT
101.70 Ω/km
Gas Injected Foam FEP
.170"
83%
AL Foil
60% AL Braid
9.7 Ω/MFT
31.8 Ω/km Plenum PVC
PVDF
.020"
.244" x .495" 16.2 53.1 73
IP181CVQ6 18 AWG
Solid CCS
31.93 Ω/MFT
101.70 Ω/km
Gas Injected Foam FEP
.170"
83%
AL Foil
60% AL Braid
AL Foil
40% AL Braid
4.0 Ω/MFT
13.1 Ω/km
PVDF
.020"
.260" 16.2 53.1 54
IP182CVQ6 (2) 18 AWG
Solid CCS
31.93 Ω/MFT
101.70 Ω/km
Gas Injected Foam FEP
.170"
83%
AL Foil
60% AL Braid
AL Foil
40% AL Braid
4.0 Ω/MFT
13.1 Ω/km
PVDF
.020"
.260" x .535" 16.2 53.1 105
Attenuation
Frequency
MHz
Nominal Attenuation
(dB/100ft)
Nominal Attenuation
(dB/100m)
5 0.45 1.47
55 1.58 5.17
100 1.98 6.47
400 4.47 14.62
700 5.96 19.49
1000 7.97 26.06
1450 10.27 33.58
2000 12.60 41.20
Specifications
Part Number Conductor
(Type, DCR)
Dielectric Type
Nominal O.D.
V.P.
Shield Type
Coverage
Nominal D.C.R.
Jacket
(Type, Thickness)
Jacket O.D. Nominal Capacitance
Weight (lbs)
Per Mft.
pF/ft pF/m
IP181VT9 18 AWG
Solid BC
6.4 Ω/MFT
21.0 Ω/km
Gas Injected Foam FEPE
.170"
83%
AL Foil
95% TC Braid
2.0 Ω/MFT
6.6 Ω/km
SGPVC, .020" .240" 16.2 53.1 44
Attenuation
Frequency
MHz
Nominal Attenuation
(dB/100ft)
Nominal Attenuation
(dB/100m)
1 0.22 0.72
3.6 0.45 1.48
10 0.73 2.39
71.5 1.72 5.64
135 2.35 7.71
270 3.36 11.02
360 3.98 13.05
720 6.08 19.94
1000 7.23 23.71
1500 9.13 29.95
2250 11.52 37.79
3000 13.64 44.7

Additional Notes:
Other Jacket Colors Available - 25,000 ft. Minimum Order Required
Also Available for Outdoor/Direct Burial Applications

Go Back to Short Specifications Product Category Go Back to Products Main Page Part Number Index

While every effort is made to insure that the product specifications are current and accurate, they are subject to change without notification. Please contact Isotec for specification verification if required.