Coaxial Cable

Broadband/MATV - 75Ω

RG-6 Riser

RG-6 Riser
Approvals:


Applications:

Temperature:

Conductor:

Insulation:

Shield:


Jacket:
UL Type CMR or CMG
(Non-Riser is CM)

75Ω Broadband/MATVR, CATVR

-20°C to 75°C

Copper Clad Steel or Bare Copper

Gas Injected Foam PE

Aluminum or Tinned Copper Braid
Aluminum Mylar Foil

Riser Rated Black PVC

Cross Section

Specifications
Part Number Conductor
(Type, DCR)
Dielectric Type
Nominal O.D.
V.P.
Shield Type
Coverage
Nominal D.C.R.
Jacket
(Type, Thickness)
Jacket O.D. Nominal Capacitance
Weight (lbs)
Per Mft.
pF/ft pF/m
IR181CV4 18 AWG
Solid CCS
31.93 Ω/MFT
101.70 Ω/km
Gas Injected Foam PE
.180"
83%
AL Foil
40% AL Braid
14.9 Ω/MFT
48.9 Ω/km
Riser Rated PVC
.030"
.272" 16.2 53.1 28
IR181CV6 18 AWG
Solid CCS
31.93 Ω/MFT
101.70 Ω/km
Gas Injected Foam PE
.180"
83%
AL Foil
60% AL Braid
9.7 Ω/MFT
31.8 Ω/km
Riser Rated PVC
.030"
.272" 16.2 53.1 31
IR181CV9 18 AWG
Solid CCS
31.93 Ω/MFT
101.70 Ω/km
Gas Injected Foam PE
.180"
83%
AL Foil
90% AL Braid
7.0 Ω/MFT
23.0 Ω/km
Riser Rated PVC
.030"
.272" 16.2 53.1 32
IR182CV6 (2) 18 AWG
Solid CCS
31.93 Ω/MFT
101.70 Ω/km
Gas Injected Foam PE
.180"
83%
AL Foil
60% AL Braid
9.7 Ω/MFT
31.8 Ω/km
Riser Rated PVC
.030"
.272" x .580" 16.2 53.1 65
IR181CVQ6 18 AWG
Solid CCS
31.93 Ω/MFT
101.70 Ω/km
Gas Injected Foam PE
.180"
83%
AL Foil
60% AL Braid
AL Foil
40% AL Braid
4.0 Ω/MFT
13.1 Ω/km
Riser Rated PVC
.032"
.298" 16.2 53.1 36
IR182CVQ6 (2) 18 AWG
Solid CCS
31.93 Ω/MFT
101.70 Ω/km
Gas Injected Foam PE
.180"
83%
AL Foil
60% AL Braid
AL Foil
40% AL Braid
4.0 Ω/MFT
13.1 Ω/km
Riser Rated PVC
.032"
.298" x .615" 16.2 53.1 73
Attenuation
Frequency
MHz
Nominal Attenuation
(dB/100ft)
Nominal Attenuation
(dB/100m)
1 0.24 0.78
10 0.65 2.12
50 1.39 4.53
100 1.92 6.27
200 2.65 8.68
400 3.78 12.37
700 3.98 13.01
900 5.83 19.05
1000 6.15 20.12
1200 6.81 22.28
1450 7.56 24.72
1800 8.55 27.96
2400 9.13 29.86
Specifications
Part Number Conductor
(Type, DCR)
Dielectric Type
Nominal O.D.
V.P.
Shield Type
Coverage
Nominal D.C.R.
Jacket
(Type, Thickness)
Jacket O.D. Nominal Capacitance
Weight (lbs)
Per Mft.
pF/ft pF/m
IR181VT9 18 AWG
Solid BC
6.4 Ω/MFT
21.0 Ω/km
Gas Injected Foam PE
.180"
83%
AL Foil
95% TC Braid
2.0 Ω/MFT
6.6 Ω/km
Riser Rated PVC
.032"
.727" 16.2 53.1 44
Attenuation
Frequency
MHz
Nominal Attenuation
(dB/100ft)
Nominal Attenuation
(dB/100m)
Frequency
MHz
Nominal Attenuation
(dB/100ft)
Nominal Attenuation
(dB/100m)
1 0.02 0.08 180 2.29 7.49
3.58 0.22 0.72 270 2.84 9.30
5 0.31 1.01 360 3.34 10.96
7 0.39 1.28 540 4.18 13.71
10 0.48 1.57 720 4.92 16.12
67.5 1.42 4.66 750 4.98 16.33
71.5 1.45 4.77 1000 5.79 18.99
88.5 1.62 5.30 1500 7.38 24.21
100 1.71 5.61 2000 8.25 27.07
135 1.97 6.46 2250 8.84 29.01
143 2.03 6.66 3000 10.46 34.31

Additional Notes:
Other Jacket Colors Available - 25,000 ft. Minimum Order Required
All Constructions are Available in Non-riser with Identical Electrical Characteristics
Also Available for Outdoor/Direct Burial Applications

Go Back to Short Specifications Product Category Go Back to Products Main Page Part Number Index

While every effort is made to insure that the product specifications are current and accurate, they are subject to change without notification. Please contact Isotec for specification verification if required.