Black Line Top Header Black Line
Top Subnav
Black Line barhomeProductsCorporateCustomize Your CableResources & Referencesbar Black Line
Black Line Broadband/MATV - 75? Coax Cables Coaxial Black Line
Black Line Black Line
RG-6 Plenum
RG-6 Plenum Rated Broadband MATV Coaxial Cable
Approvals: UL Type CMP

Applications:   75Ω Broadband/MATVP, CATVP

Temperature: 0°C to 75°C

Conductor:   Annealed Solid Bare Copper or Copper Clad Steel

Insulation:   Gas Injected Foam FEP

Shield:   Aluminum or Tinned Copper Braid
Aluminum Mylar Foil

Jacket:   Plenum Natural PVC, PVDF, or SGPVC

 
Black Line
Specifications
Part # Conductor
(Type, DCR)
Dielectric Type
Nominal O.D
V. P.
Shield Type
Coverage
Nominal D.C.R.
Jacket
(Type, Thickness)
Jacket O.D. Nominal
Capacitance
pF/ft.   pF/m
Weight
Per MFT (lbs)
  IP181CV4
Non (UL)
18 AWG
Solid CCS
31.93 Ω/MFT
101.70 Ω/km
Gas Injected Foam FEP
.170"
83%
AL Foil
40% AL Braid
14.9 Ω/MFT
48.9 Ω/km
Plenum PVC
.020"
.244" 16.2 53.1 35
  IP181CV6 18 AWG
Solid CCS
31.93 Ω/MFT
101.70 Ω/km
Gas Injected Foam FEP
.170"
83%
AL Foil
60% AL Braid
9.7 Ω/MFT
31.8 Ω/km
Plenum PVC
.020"
.244" 16.2 53.1 32
  IP181CV9 18 AWG
Solid CCS
31.93 Ω/MFT
101.70 Ω/km
Gas Injected Foam FEP
.170"
83%
AL Foil
90% AL Braid
7.0 Ω/MFT
23.0 Ω/km
Plenum PVC
.020"
.244" 16.2 53.1 38
  IP182CV6 (2) 18 AWG
Solid CCS
31.93 Ω/MFT
101.70 Ω/km
Gas Injected Foam FEP
.170"
83%
AL Foil
60% AL Braid
9.7 Ω/MFT
31.8 Ω/km
Plenum PVC
.020"
.244" x .495" 16.2 53.1 73
  IP181CVQ6 18 AWG
Solid CCS
31.93 Ω/MFT
101.70 Ω/km
Gas Injected Foam FEP
.170"
83%
AL Foil
60% AL Braid
AL Foil
40% AL Braid
4.0 Ω/MFT
13.1 Ω/km
PVDF
.020"
.260" 16.2 53.1 54
  IP182CVQ6 (2) 18 AWG
Solid CCS
31.93 Ω/MFT
101.70 Ω/km
Gas Injected Foam FEP
.170"
83%
AL Foil
60% AL Braid
AL Foil
40% AL Braid
4.0 Ω/MFT
13.1 Ω/km
PVDF
.020"
.260" x .535" 16.2 53.1 105
Attenuation
Frequency
MHz
Nominal Attenuation
(dB/100ft)
Nominal Attenuation
(dB/100m)
Black Line
  5 0.45 1.47
  55 1.58 5.17
  100 1.98 6.47
  400 4.47 14.62
  700 5.96 19.49
  1000 7.97 26.06
  1450 10.27 33.58
  2000 12.60 41.20
Specifications
Part # Conductor
(Type, DCR)
Dielectric Type
Nominal O.D
V. P.
Shield Type
Coverage
Nominal D.C.R.
Jacket
(Type, Thickness)
Jacket O.D. Nominal
Capacitance
pF/ft.   pF/m
Weight
Per MFT (lbs)
  IP181VT9 18 AWG
Solid BC
6.4 Ω/MFT
21.0 Ω/km
Gas Injected Foam FEPE
.170"
83%
AL Foil
95% TC Braid
2.0 Ω/MFT
6.6 Ω/km
SGPVC, .020" .240" 16.2 53.1 44
Attenuation
Frequency
MHz
Nominal Attenuation
(dB/100ft)
Nominal Attenuation
(dB/100m)
Black Line
  1 0.22 0.72
  3.6 0.45 1.48
  10 0.73 2.39
  71.5 1.72 5.64
  135 2.35 7.71
  270 3.36 11.02
  360 3.98 13.05
  720 6.08 19.94
  1000 7.23 23.71
  1500 9.13 29.95
  2250 11.52 37.79
  3000 13.64 44.7
Additional Notes:
  Other Jacket Colors Available - 25,000 ft. Minimum Order Required
Also Available for Outdoor/Direct Burial Applications

While every effort is made to insure the product specifications on this web site and all other collateral (i.e. catalogs, printed materials) are current, they are subject to change without notification.
Black Line
Black Line Footer bullet
Distributor Appointment Form Find a Distributor Specials & Promotions Featured Product Contact Isotec, Inc. Sitemap Legal Disclaimers and Copyright Information