Black Line Top Header Black Line
Top Subnav
Black Line barhomeProductsCorporateCustomize Your CableResources & Referencesbar Black Line
Black Line Broadband/MATV - 75? Coax Cables Coaxial Black Line
Black Line Black Line
RG-6 Riser
RG6 Riser Rated Coax for Broadband and MATV
Approvals: UL Type CMR or CMG
(Non-Riser is CM)

Applications:   75Ω Broadband/MATVR, CATVR

Temperature: -20°C to 75°C

Conductor:   Copper Clad Steel or Bare Copper

Insulation:   Gas Injected Foam PE

Shield:   Aluminum or Tinned Copper Braid
Aluminum Mylar Foil

Jacket:   Riser Rated Black PVC

 
Black Line
Specifications
Part # Conductor
(Type, DCR)
Dielectric Type
Nominal O.D
V. P.
Shield Type
Coverage
Nominal D.C.R.
Jacket
(Type, Thickness)
Jacket O.D. Nominal
Capacitance
pF/ft.   pF/m
Weight
Per MFT (lbs)
  IR181CV4 18 AWG
Solid CCS
31.93 Ω/MFT
101.70 Ω/km
Gas Injected Foam PE
.180"
83%
AL Foil
40% AL Braid
14.9 Ω/MFT
48.9 Ω/km
Riser Rated PVC
.030"
.272" 16.2 53.1 28
  IR181CV6 18 AWG
Solid CCS
31.93 Ω/MFT
101.70 Ω/km
Gas Injected Foam PE
.180"
83%
AL Foil
60% AL Braid
9.7 Ω/MFT
31.8 Ω/km
Riser Rated PVC
.030"
.272" 16.2 53.1 31
  IR181CV9 18 AWG
Solid CCS
31.93 Ω/MFT
101.70 Ω/km
Gas Injected Foam PE
.180"
83%
AL Foil
90% AL Braid
7.0 Ω/MFT
23.0 Ω/km
Riser Rated PVC
.030"
.272" 16.2 53.1 32
  IR182CV6 (2) 18 AWG
Solid CCS
31.93 Ω/MFT
101.70 Ω/km
Gas Injected Foam PE
.180"
83%
AL Foil
60% AL Braid
9.7 Ω/MFT
31.8 Ω/km
Riser Rated PVC
.030"
.272" x .580" 16.2 53.1 65
  IR181CVQ6 18 AWG
Solid CCS
31.93 Ω/MFT
101.70 Ω/km
Gas Injected Foam PE
.180"
83%
AL Foil
60% AL Braid
AL Foil
40% AL Braid
4.0 Ω/MFT
13.1 Ω/km
Riser Rated PVC
.032"
.298" 16.2 53.1 36
  IR182CVQ6 (2) 18 AWG
Solid CCS
31.93 Ω/MFT
101.70 Ω/km
Gas Injected Foam PE
.180"
83%
AL Foil
60% AL Braid
AL Foil
40% AL Braid
4.0 Ω/MFT
13.1 Ω/km
Riser Rated PVC
.032"
.298" x .615" 16.2 53.1 73
Attenuation
Frequency
MHz
Nominal Attenuation
(dB/100ft)
Nominal Attenuation
(dB/100m)
Black Line
  1 0.24 0.78
  10 0.65 2.12
  50 1.39 4.53
  100 1.92 6.27
  200 2.65 8.68
  400 3.78 12.37
  700 3.98 13.01
  900 5.83 19.05
  1000 6.15 20.12
  1200 6.81 22.28
  1450 7.56 24.72
  1800 8.55 27.96
  2400 9.13 29.86
Specifications
Part # Conductor
(Type, DCR)
Dielectric Type
Nominal O.D
V. P.
Shield Type
Coverage
Nominal D.C.R.
Jacket
(Type, Thickness)
Jacket O.D. Nominal
Capacitance
pF/ft.   pF/m
Weight
Per MFT (lbs)
  IR181VT9 18 AWG
Solid BC
6.4 Ω/MFT
21.0 Ω/km
Gas Injected Foam PE
.180"
83%
AL Foil
95% TC Braid
2.0 Ω/MFT
6.6 Ω/km
Riser Rated PVC
.032"
.272" 16.2 53.1 44
Attenuation
Frequency
MHz
Nominal Attenuation
(dB/100ft)
Nominal Attenuation
(dB/100m)
Frequency
MHz
Nominal Attenuation
(dB/100ft)
Nominal Attenuation
(dB/100m)
  1 0.02 0.08 Black Line 180 2.29 7.49
  3.58 0.22 0.72 270 2.84 9.30
  5 0.31 1.01 360 3.34 10.96
  7 0.39 1.28 540 4.18 13.71
  10 0.48 1.57 720 4.92 16.12
  67.5 1.42 4.66 750 4.98 16.33
  71.5 1.45 4.77 1000 5.79 18.99
  88.5 1.62 5.30 1500 7.38 24.21
  100 1.71 5.61 2000 8.25 27.07
  135 1.97 6.46 2250 8.84 29.01
  143 2.03 6.66 3000 10.46 34.31
Additional Notes:
  Other Jacket Colors Available - 25,000 ft. Minimum Order Required
All Constructions are Available in Non-riser with Identical Electrical Characteristics
Also Available for Outdoor/Direct Burial Applications

While every effort is made to insure the product specifications on this web site and all other collateral (i.e. catalogs, printed materials) are current, they are subject to change without notification.
Black Line
Black Line Footer bullet
Distributor Appointment Form Find a Distributor Specials & Promotions Featured Product Contact Isotec, Inc. Sitemap Legal Disclaimers and Copyright Information