| Part Number | Conductor (Type, DCR) |
Dielectric Type Nominal O.D. V.P. |
Shield Type Coverage Nominal D.C.R. |
Jacket (Type, Thickness) |
Jacket O.D. | Nominal Capacitance |
Weight (lbs) Per Mft. |
|
|---|---|---|---|---|---|---|---|---|
| pF/ft | pF/m | |||||||
| IR20HEC Headend Cable |
20 AWG Solid SPCCS 10.7 Ω/MFT 35.1 Ω/km |
Gas Injected Foam PE .146" 84% |
AL Foil 95% AL Braid AL Foil 95% AL Braid 6.0 Ω/MFT 19.7 Ω/km |
Riser Rated PVC .035" |
.270" | 16.2 | 53.1 | 35 |
| IR20HEC3 Headend Cable w/ 3 Audio Pairs |
20 AWG Solid SPCCS 10.7 Ω/MFT 35.1 Ω/km |
Gas Injected Foam PE .146" 84% |
AL Foil 95% AL Braid AL Foil 95% AL Braid 6.0 Ω/MFT 19.7 Ω/km |
Riser Rated PVC .035" |
.270" x .535" | 16.2 | 53.1 | 50 |
| Conductor (Type, DCR) |
Number of Pairs |
Insulation (Type, Thickness |
Shield |
|---|---|---|---|
| 22 AWG BC EPS 7/30 TC Drain 14.8 Ω/MFT |
3 | PE, .010" (Nom. Wall) |
100% Foil 24 AWG 7/32 TC Drain |
| Frequency MHz |
Nominal Attenuation (dB/100ft) |
Nominal Attenuation (dB/100m) |
|---|---|---|
| 5 | 0.77 | 2.53 |
| 55 | 1.98 | 6.47 |
| 83 | 2.35 | 7.68 |
| 187 | 3.35 | 10.94 |
| 211 | 3.54 | 11.59 |
| 250 | 3.83 | 12.51 |
| 300 | 4.21 | 13.78 |
| 350 | 4.51 | 14.74 |
| 400 | 4.84 | 15.58 |
| 450 | 5.11 | 16.71 |
| 500 | 5.68 | 18.58 |
| 550 | 5.94 | 19.44 |
| 600 | 6.21 | 20.30 |
| 750 | 6.90 | 22.57 |
| 865 | 7.44 | 24.32 |
| 1000 | 7.98 | 26.09 |
Additional Notes:
Other Jacket Colors Available - 25,000 ft. Minimum Order Required
All Constructions are Available in Non-riser with Identical Electrical Characteristics
Also Available for Outdoor/Direct Burial Applications

While every effort is made to insure that the product specifications are current and accurate, they are subject to change without notification. Please contact Isotec for specification verification if required.