| Part Number | Conductor (Type, DCR) |
Dielectric Type Nominal O.D V. P. |
Shield Type Coverage Nominal D.C.R. |
Jacket (Type, Thickness) |
Jacket O.D. | Nominal Capacitance |
Weight (lbs) Per Mft. |
|
|---|---|---|---|---|---|---|---|---|
| pF/ft | pF/m | |||||||
| IR201V59 | 20 AWG Solid BC 10.2 Ω/MFT 32.8 Ω/km |
Gas Injected Foam PE .144" 83% |
95% BC Braid 2.6 Ω/MFT 8.6 Ωkm |
Riser Rated PVC .032" |
.242" | 16.2 | 53.1 | 36 |
| I201V59 | Non-riser Rated Version with Identical Electrical Characteristics | |||||||
| Frequency MHz |
Nominal Attenuation (dB/100ft) |
Nominal Attenuation (dB/100m) |
|---|---|---|
| 1 | .23 | 0.75 |
| 10 | .78 | 2.55 |
| 50 | 1.79 | 5.86 |
| 100 | 2.56 | 8.40 |
| 200 | 3.70 | 12.15 |
| 400 | 5.34 | 17.52 |
| 700 | 7.10 | 23.29 |
| 900 | 8.01 | 26.27 |
| 1000 | 8.51 | 27.91 |
| Part Number | Conductor (Type, DCR) |
Dielectric Type Nominal O.D V. P. |
Shield Type Coverage Nominal D.C.R. |
Jacket (Type, Thickness) |
Jacket O.D. | Nominal Capacitance |
Weight (lbs) Per Mft. |
|
|---|---|---|---|---|---|---|---|---|
| pF/ft | pF/m | |||||||
| IP201V59 | 20 AWG Solid BC 10.1 Ω/MFT 21.0 Ω/km |
Gas Injected Foam FEP .138" 83% |
95% BC Braid 2.6 Ω/MFT 8.5 Ω/km |
PL-PVC .020" |
.193" | 16.2 | 53.1 | 36 |
| Frequency MHz |
Nominal Attenuation (dB/100ft) |
Nominal Attenuation (dB/100m) |
|---|---|---|
| 1 | 0.33 | 1.08 |
| 5 | 0.52 | 1.70 |
| 10 | 0.83 | 2.71 |
| 50 | 1.86 | 6.07 |
| 100 | 2.65 | 8.65 |
| 400 | 5.47 | 17.85 |
| 750 | 7.86 | 25.65 |
| 1000 | 9.54 | 31.13 |
| Part Number | Conductor (Type, DCR) |
Dielectric Type Nominal O.D V. P. |
Shield Type Coverage Nominal D.C.R. |
Jacket (Type, Thickness) |
Jacket O.D. | Nominal Capacitance |
Weight (lbs) Per Mft. |
|
|---|---|---|---|---|---|---|---|---|
| pF/ft | pF/m | |||||||
| I201V59D Outdoor Non (UL) |
20 AWG Solid BC 10.2 Ω/MFT 32.8 Ω/km |
Gas Injected Foam PE .144" 83% |
95% BC Braid 2.6 Ω/MFT 8.5 Ω/km |
PE w/ Floodant Tape .025" |
.242" | 16.3 | 53.5 | 30 |
| Frequency MHz |
Nominal Attenuation (dB/100ft) |
Nominal Attenuation (dB/100m) |
|---|---|---|
| 1 | 0.23 | 0.75 |
| 10 | 0.78 | 2.55 |
| 50 | 1.79 | 5.86 |
| 100 | 2.56 | 8.40 |
| 200 | 3.70 | 12.15 |
| 400 | 5.34 | 17.52 |
| 700 | 7.10 | 23.29 |
| 900 | 8.01 | 26.27 |
| 1000 | 8.51 | 27.91 |
| Part Number | Conductor (Type, DCR) |
Dielectric Type Nominal O.D V. P. |
Shield Type Coverage Nominal D.C.R. |
Jacket (Type, Thickness) |
Jacket O.D. | Nominal Capacitance |
Weight (lbs) Per Mft. |
|
|---|---|---|---|---|---|---|---|---|
| pF/ft | pF/m | |||||||
| IR201CV59 | 20 AWG Solid CCS 46.01 Ω/MFT 51.03 Ω/km |
Gas Injected Foam PE .144" 83% |
95% BC Braid 2.6 Ω/MFT 8.5 Ω/km |
PVC Riser .032" |
.242" | 16.3 | 53.5 | 30 |
| Frequency MHz |
Nominal Attenuation (dB/100ft) |
Nominal Attenuation (dB/100m) |
|---|---|---|
| 1 | 0.23 | 0.75 |
| 10 | 0.78 | 2.55 |
| 50 | 1.79 | 5.86 |
| 100 | 2.56 | 8.40 |
| 200 | 3.70 | 12.15 |
| 400 | 5.34 | 17.52 |
| 700 | 7.10 | 23.29 |
| 900 | 8.01 | 26.27 |
| 1000 | 8.51 | 27.91 |
| Part Number | Conductor (Type, DCR) |
Dielectric Type Nominal O.D V. P. |
Shield Type Coverage Nominal D.C.R. |
Jacket (Type, Thickness) |
Jacket O.D. | Nominal Capacitance |
Weight (lbs) Per Mft. |
|
|---|---|---|---|---|---|---|---|---|
| pF/ft | pF/m | |||||||
| IR221SV59 | 22 AWG 19/34 BC 14.3 Ω/MFT 49.9 Ω/km |
Gas Injected Foam PE .144" 83% |
95% BC Braid 2.6 Ω/MFT 8.5 Ω/km |
PVC .032" |
.242" | 16.2 | 53.1 | 36 |
| Frequency MHz |
Nominal Attenuation (dB/100ft) |
Nominal Attenuation (dB/100m) |
|---|---|---|
| 1 | 0.30 | 0.98 |
| 3.6 | 0.57 | 1.87 |
| 10 | 0.89 | 2.92 |
| 71.5 | 2.23 | 7.31 |
| 135 | 3.12 | 10.23 |
| 270 | 4.49 | 14.73 |
| 360 | 5.40 | 17.71 |
| 720 | 8.14 | 26.70 |
| 1000 | 10.10 | 33.13 |
Additional Notes:
Other Jacket Colors Available - 25,000 ft. Minimum Order Required
All Constructions are Available in Non-riser with Identical Electrical Characteristics
Also Available for Outdoor/Direct Burial Applications

While every effort is made to insure that the product specifications are current and accurate, they are subject to change without notification. Please contact Isotec for specification verification if required.