Traffic Camera Cable

IMSA 50-2 Loop & Lead-in

Composite Cable

Composite Cable
Approvals:

Applications:

Temperature:

Voltage:

Conductor:

Insulation:


Shield:

Jacket:

Color Code:
N/A

Iteris Traffic Control

-20°C to 75°C

600 Volt

Solid Bare Copper

Component 1: PE
Component 2: PVC

Component 1: Tinned Copper

Black PE

Black, White, Green

Cross Section

Overall Specifications
Part Number Jacket
(Type, Thickness)
Jacket O.D. Copper Weight
Lbs/MFT
Weight (lbs)
Per Mft.
I59PVCC-00 18 AWG
Solid BC
6.2 Ω/MFT
.592" 59.86 168
Component 1 Specifications
Conductor
(Type, DCR)
Insulation
(Type, Thickness)
Shield
(Type, Thickness)
Jacket
(Type, Thickness, O.D.)
Nominal Capacitance
pF/ft pF/m
20 AWG
Solid BC
10.2 Ω/MFT
33.1 Ω/MFT
Solid PE, .198" 98% TC Braid x 2
1.1 Ω/MFT
3.6 Ω/MFT
PE, .035", .304" 20.9 68.7
Attenuation
Frequency
MHz
Nominal Attenuation
(dB/100ft)
Nominal Attenuation
(dB/100m)
Frequency
MHz
Nominal Attenuation
(dB/100ft)
Nominal Attenuation
(dB/100m)
1 0.14 0.46 135 2.58 8.46
3.85 0.47 1.54 143 2.62 8.59
5 0.54 1.77 180 2.79 9.15
7 0.62 2.03 270 4.36 14.30
10 0.68 2.23 360 4.98 16.33
67.5 2.02 6.63 540 6.68 21.91
71.5 2.10 6.89 720 7.82 25.65
100 2.50 8.20 1000 9.18 30.11
Component 2 Specifications
Conductor
(Type, DCR)
Number of
Conductors
Insulation
(Type, Thickness)
Jacket
(Type, Thickness, O.D.)
Nominal Capacitance
pF/ft pF/m
16 AWG
19/29 BC
4.0 Ω/MFT
3 PVC, .030" PVC Pressure with tape & Fillers
.040"
20.9 .340"

Additional Notes:
*Capacitance Between Conductors
**Capacitance Between One Conductor and the Other Connected to the Shield

Go Back to Short Specifications Product Category Go Back to Products Main Page Part Number Index