| Part Number | Jacket (Type, Thickness) |
Jacket O.D. | Copper Weight Lbs/MFT |
Weight (lbs) Per Mft. |
|---|---|---|---|---|
| I59PVCC-00 | 18 AWG Solid BC 6.2 Ω/MFT |
.592" | 59.86 | 168 |
| Conductor (Type, DCR) |
Insulation (Type, Thickness) |
Shield (Type, Thickness) |
Jacket (Type, Thickness, O.D.) |
Nominal Capacitance |
|
|---|---|---|---|---|---|
| pF/ft | pF/m | ||||
| 20 AWG Solid BC 10.2 Ω/MFT 33.1 Ω/MFT |
Solid PE, .198" | 98% TC Braid x 2 1.1 Ω/MFT 3.6 Ω/MFT |
PE, .035", .304" | 20.9 | 68.7 |
| Frequency MHz |
Nominal Attenuation (dB/100ft) |
Nominal Attenuation (dB/100m) |
Frequency MHz |
Nominal Attenuation (dB/100ft) |
Nominal Attenuation (dB/100m) |
|---|---|---|---|---|---|
| 1 | 0.14 | 0.46 | 135 | 2.58 | 8.46 |
| 3.85 | 0.47 | 1.54 | 143 | 2.62 | 8.59 |
| 5 | 0.54 | 1.77 | 180 | 2.79 | 9.15 |
| 7 | 0.62 | 2.03 | 270 | 4.36 | 14.30 |
| 10 | 0.68 | 2.23 | 360 | 4.98 | 16.33 |
| 67.5 | 2.02 | 6.63 | 540 | 6.68 | 21.91 |
| 71.5 | 2.10 | 6.89 | 720 | 7.82 | 25.65 |
| 100 | 2.50 | 8.20 | 1000 | 9.18 | 30.11 |
| Conductor (Type, DCR) |
Number of Conductors |
Insulation (Type, Thickness) |
Jacket (Type, Thickness, O.D.) |
Nominal Capacitance |
|
|---|---|---|---|---|---|
| pF/ft | pF/m | ||||
| 16 AWG 19/29 BC 4.0 Ω/MFT |
3 | PVC, .030" | PVC Pressure with tape & Fillers .040" |
20.9 | .340" |
Additional Notes:
*Capacitance Between Conductors
**Capacitance Between One Conductor and the Other Connected to the Shield

While every effort is made to insure that the product specifications are current and accurate, they are subject to change without notification. Please contact Isotec for specification verification if required.