Traffic Camera Cable

IMSA 51-5 Loop & Lead-in

Unshielded PVC Jacket - Stranded Bare Copper

Unshielded PVC Jacket - Stranded Bare Copper
Approvals:

Applications:

Temperature:

Voltage:

Conductor:

Insulation:

Jacket:
Meets IMSA Standard 51-5

Inductance Loop Detector

-20°C to 75°C

600 Volt

Stranded Bare Copper

PVC with Nylon

Black Loose Tube PVC

Cross Section

Specifications
Part Number Conductor
(Type, DCR)
Number of
Conductors
Insulation
(Type, Thickness)
Nominal Jacket
Thickness
Nominal O.D. Weight (lbs)
Per Mft.
IL121BA19 12 AWG
19/25 BC
1.59 Ω/MFT
1 PVC, .015"
Nylon, .005"
.030" .260" 38
IL141BA19 14 AWG
19/27 BC
2.53 Ω/MFT
1 PVC, .015"
Nylon, .005"
.030" .250" 30

Additional Notes:
Other Jacket Colors Available - 25,000 ft. Minimum Order Required

Go Back to Short Specifications Product Category Go Back to Products Main Page Part Number Index

While every effort is made to insure that the product specifications are current and accurate, they are subject to change without notification. Please contact Isotec for specification verification if required.