Multi-pair and Multi-conductor

Multi-pair Non- Plenum

Shielded Pairs - Common Drain

Shielded Pairs - Common Drain
Approvals:




Applications:


Temperature:

Voltage:

Conductor:

Insulation:

Shield:


Jacket:


Color Code:
UL Type CMP and /or CL3P
NEC Article 760, 800
UL Subject 13, 444
California State Fire Marshal

Security systems, Intercoms, Background Music, Sound and Audio

0°C to 75°C

300 Volt

Annealed Stranded Bare Copper

Plenum PVC

Foil Free Edge Tape Provides isolated Shield
Stranded Tinned Copper Drain Wire

Plenum Rated Natural PVC
Ripcord

1 Pair Black, Red
2 Pair Green, White

Cross Section

Specifications
Part Number Conductor
(Type, DCR)
Number of
Pairs
Insulation
(Type, Thickness)
Nominal Jacket
Thickness
Nominal O.D. Nominal Capacitance
Weight (lbs)
Per Mft.
pF/ft* pF/ft**
IP222CAPS 22 AWG
7/30 BC
14.8 Ω/MFT
2 SGPVC, .008" .015" .140" 40.8 73 21

Additional Notes:
Other Jacket Colors Available - 25,000 ft. Minimum Order Required
*Capacitance Between Conductors
**Capacitance Between One Conductor and the Other Connected to the Shield

Go Back to Short Specifications Product Category Go Back to Products Main Page Part Number Index

While every effort is made to insure that the product specifications are current and accurate, they are subject to change without notification. Please contact Isotec for specification verification if required.