Coaxial Cable

Transmission and Data - 50Ω

RG-58 PE (Outdoor/Direct Burial)

RG-58 PE (outdoor/Direct Burial)
Approvals:


Applications:

Temperature:

Conductor:

Insulation:

Shield:

Jacket:
Non(UL)
Outdoor

Transmission and Data 50Ω

-40°C to 75°C

Stranded Tinned Copper

Solid PE

Tinned Copper

Black PE

Cross Section

Specifications
Part Number Conductor
(Type, DCR)
Dielectric Type
Nominal O.D.
V.P.
Shield Type
Coverage
Nominal D.C.R.
Jacket
(Type, Thickness)
Jacket O.D. Nominal Capacitance
Weight (lbs)
Per Mft.
pF/ft pF/m
I20158TT9D
Outdoor
20 AWG
19/32 TC
8.8 Ω/MFT
28.9 Ω/km
Solid PE
.116"
66%
95% TC Braid
4.1 Ω/MFT
13.5 Ω/km
PE, .030" .195" 30.5 100 24
Attenuation
Frequency
MHz
Nominal Attenuation
(dB/100ft)
Nominal Attenuation
(dB/100m)
1 0.6 2.0
10 1.5 4.9
50 4.5 14.8
100

4.9

16.1
200 9.1 29.9
400 11.5

37.7

700 17.0 55.8
900 20.0 65.6
1000 21.5 70.5

Additional Notes:
Other Jacket Colors Available - 25,000 ft. Minimum Order Required

Go Back to Short Specifications Product Category Go Back to Products Main Page Part Number Index