| Part Number | Conductor (Type, DCR) |
Dielectric Type Nominal O.D. V.P. |
Shield Type Coverage Nominal D.C.R. |
Jacket (Type, Thickness) |
Jacket O.D. | Nominal Capacitance |
Weight (lbs) Per Mft. |
|
|---|---|---|---|---|---|---|---|---|
| pF/ft | pF/m | |||||||
| I20158BT9 | 20 AWG 19/32 TC 8.8 Ω/MFT 28.9 Ω/km |
Gas Injected Foam PE .114" 82% |
AL Foil 55% TC Braid 17 Ω/MFT 55.8 Ω/km |
PVC, .030" | .194" | 26 | 85.3 | 21 |
| Frequency MHz |
Nominal Attenuation (dB/100ft) |
Nominal Attenuation (dB/100m) |
|---|---|---|
| 1 | 0.4 | 1.3 |
| 10 | 1.4 | 4.6 |
| 50 | 2.8 | 9.2 |
| 100 | 3.8 | 12.5 |
| 200 | 5.4 | 17.7 |
| 400 | 7.9 | 25.9 |
| 700 | 11.1 | 36.4 |
| 900 | 12.8 | 42.0 |
| 1000 | 13.9 | 45.6 |
| Part Number | Conductor (Type, DCR) |
Dielectric Type Nominal O.D. V.P. |
Shield Type Coverage Nominal D.C.R. |
Jacket (Type, Thickness) |
Jacket O.D. | Nominal Capacitance |
Weight (lbs) Per Mft. |
|
|---|---|---|---|---|---|---|---|---|
| pF/ft | pF/m | |||||||
| I20158TT9 | 20 AWG 19/32 TC 8.8 Ω/MFT 28.9 Ω/km |
Gas Injected Foam PE .114" 82% |
95% TC Braid 4.1 Ω/MFT 13.5 Ω/km |
PVC, .030" | .195" | 28.5 | 93.5 | 27 |
| Frequency MHz |
Nominal Attenuation (dB/100ft) |
Nominal Attenuation (dB/100m) |
|---|---|---|
| 1 | 0.4 | 1.3 |
| 10 | 1.3 | 4.3 |
| 50 | 3.1 | 10.2 |
| 100 | 4.5 | 14.8 |
| 200 | 6.6 | 21.7 |
| 400 | 10.0 | 32.8 |
| 700 | 14.2 | 46.6 |
| 900 | 16.6 | 54.5 |
| 1000 | 18.1 | 59.4 |
| Part Number | Conductor (Type, DCR) |
Dielectric Type Nominal O.D. V.P. |
Shield Type Coverage Nominal D.C.R. |
Jacket (Type, Thickness) |
Jacket O.D. | Nominal Capacitance |
Weight (lbs) Per Mft. |
|
|---|---|---|---|---|---|---|---|---|
| pF/ft | pF/m | |||||||
| I201158BB8 | 20 AWG Solid BC 10.3 Ω/MFT 33.8 Ω/km |
Solid PE .116" 66% |
80% BC Braid 5.6 Ω/MFT 18.4 Ω/km |
PVC, .030" | .195" | 28.5 | 93.5 | 27 |
| Frequency MHz |
Nominal Attenuation (dB/100ft) |
Nominal Attenuation (dB/100m) |
|---|---|---|
| 1 | 0.4 | 1.3 |
| 10 | 1.2 | 3.9 |
| 50 | 2.9 | 9.5 |
| 100 | 4.2 | 13.8 |
| 200 | 6.0 | 19.7 |
| 400 | 9.1 | 29.9 |
| 700 | 12.8 | 42.0 |
| 900 | 15.5 | 50.9 |
| 1000 | 16.5 | 54.1 |
| Part Number | Conductor (Type, DCR) |
Dielectric Type Nominal O.D. V.P. |
Shield Type Coverage Nominal D.C.R. |
Jacket (Type, Thickness) |
Jacket O.D. | Nominal Capacitance |
Weight (lbs) Per Mft. |
|
|---|---|---|---|---|---|---|---|---|
| pF/ft | pF/m | |||||||
| I20158BT9 | 20 AWG Solid BC 10.3 Ω/MFT 33.8 Ω/km |
Gas Injected Foam PE .116" 82% |
95% TC Braid 4.1 Ω/MFT 13.5 Ω/km |
PVC, .030" | .195" | 26.0 | 85.3 | 25 |
| Frequency MHz |
Nominal Attenuation (dB/100ft) |
Nominal Attenuation (dB/100m) |
|---|---|---|
| 1 | 0.4 | 1.3 |
| 10 | 1.1 | 3.6 |
| 50 | 2.5 | 8.2 |
| 100 | 3.8 | 12.5 |
| 200 | 5.6 | 18.4 |
| 400 | 8.5 | 27.9 |
| 700 | 11.7 | 38.4 |
| 900 | 13.7 | 44.9 |
| 1000 | 14.5 | 47.6 |
Additional Notes:
Other Jacket Colors Available - 25,000 ft. Minimum Order Required

While every effort is made to insure that the product specifications are current and accurate, they are subject to change without notification. Please contact Isotec for specification verification if required.