Coaxial Cable

Transmission and Data - 50Ω

RG-58 PVC

RG-58 PVC
Approvals:

Applications:

Temperature:

Conductor:


Insulation:

Shield:

Jacket:
UL Type CM

Transmission and Data 50Ω

-20°C to 75°C

Annealed Solid or Stranded Bare
or Tinned Copper

Solid or Gas Injected Foam PE

Bare or Tinned Copper

Black PVC

Cross Section

Specifications
Part Number Conductor
(Type, DCR)
Dielectric Type
Nominal O.D.
V.P.
Shield Type
Coverage
Nominal D.C.R.
Jacket
(Type, Thickness)
Jacket O.D. Nominal Capacitance
Weight (lbs)
Per Mft.
pF/ft pF/m
I20158BT9 20 AWG
19/32 TC
8.8 Ω/MFT
28.9 Ω/km
Gas Injected Foam PE
.114"
82%
AL Foil
55% TC Braid
17 Ω/MFT
55.8 Ω/km
PVC, .030" .194" 26 85.3 21
Attenuation
Frequency
MHz
Nominal Attenuation
(dB/100ft)
Nominal Attenuation
(dB/100m)
1 0.4 1.3
10 1.4 4.6
50 2.8 9.2
100 3.8 12.5
200 5.4 17.7
400 7.9 25.9
700 11.1 36.4
900 12.8 42.0
1000 13.9 45.6
Specifications
Part Number Conductor
(Type, DCR)
Dielectric Type
Nominal O.D.
V.P.
Shield Type
Coverage
Nominal D.C.R.
Jacket
(Type, Thickness)
Jacket O.D. Nominal Capacitance
Weight (lbs)
Per Mft.
pF/ft pF/m
I20158TT9 20 AWG
19/32 TC
8.8 Ω/MFT
28.9 Ω/km
Gas Injected Foam PE
.114"
82%
95% TC Braid
4.1 Ω/MFT
13.5 Ω/km
PVC, .030" .195" 28.5 93.5 27
Attenuation
Frequency
MHz
Nominal Attenuation
(dB/100ft)
Nominal Attenuation
(dB/100m)
1 0.4 1.3
10 1.3 4.3
50 3.1 10.2
100 4.5 14.8
200 6.6 21.7
400 10.0 32.8
700 14.2 46.6
900 16.6 54.5
1000 18.1 59.4
Specifications
Part Number Conductor
(Type, DCR)
Dielectric Type
Nominal O.D.
V.P.
Shield Type
Coverage
Nominal D.C.R.
Jacket
(Type, Thickness)
Jacket O.D. Nominal Capacitance
Weight (lbs)
Per Mft.
pF/ft pF/m
I201158BB8 20 AWG
Solid BC
10.3 Ω/MFT
33.8 Ω/km
Solid PE
.116"
66%
80% BC Braid
5.6 Ω/MFT
18.4 Ω/km
PVC, .030" .195" 28.5 93.5 27
Attenuation
Frequency
MHz
Nominal Attenuation
(dB/100ft)
Nominal Attenuation
(dB/100m)
1 0.4 1.3
10 1.2 3.9
50 2.9 9.5
100 4.2 13.8
200 6.0 19.7
400 9.1 29.9
700 12.8 42.0
900 15.5 50.9
1000 16.5 54.1
Specifications
Part Number Conductor
(Type, DCR)
Dielectric Type
Nominal O.D.
V.P.
Shield Type
Coverage
Nominal D.C.R.
Jacket
(Type, Thickness)
Jacket O.D. Nominal Capacitance
Weight (lbs)
Per Mft.
pF/ft pF/m
I20158BT9 20 AWG
Solid BC
10.3 Ω/MFT
33.8 Ω/km
Gas Injected Foam PE
.116"
82%
95% TC Braid
4.1 Ω/MFT
13.5 Ω/km
PVC, .030" .195" 26.0 85.3 25
Attenuation
Frequency
MHz
Nominal Attenuation
(dB/100ft)
Nominal Attenuation
(dB/100m)
1 0.4 1.3
10 1.1 3.6
50 2.5 8.2
100 3.8 12.5
200 5.6 18.4
400 8.5 27.9
700 11.7 38.4
900 13.7 44.9
1000 14.5 47.6

Additional Notes:
Other Jacket Colors Available - 25,000 ft. Minimum Order Required

Go Back to Short Specifications Product Category Go Back to Products Main Page Part Number Index

While every effort is made to insure that the product specifications are current and accurate, they are subject to change without notification. Please contact Isotec for specification verification if required.