RG-58 PVC
RG58
Approvals: UL Type CM

Applications:   50Ω Transmission and Data

Temperature: -20°C to 75°C

Conductor:   Annealed Solid or Stranded Bare or Tinned Copper

Insulation:   Solid or Gas Injected Foam PE

Shield:   Bare or Tinned Copper

Jacket:   Black PVC

 
Black Line
Specifications
Part # Conductor
(Type, DCR)
Dielectric Type
Nominal O.D
V. P.
Shield Type
Coverage
Nominal D.C.R.
Jacket
(Type, Thickness)
Jacket O.D. Nominal
Capacitance
pF/ft.   pF/m
Weight
Per MFT (lbs)
  I20158TT5 20 AWG
19/32 TC
8.8 Ω/MFT
28.9 Ω/km
Gas Injected Foam PE
.114"
82%
AL Foil
55% TC Braid
17 Ω/MFT
55.8 Ω/km
PVC, .030" .194" 26 85.3 21
Attenuation
Frequency
MHz
Nominal Attenuation
(dB/100ft)
Nominal Attenuation
(dB/100m)
Black Line
  1 0.4 1.3
  10 1.4 4.6
  50 2.8 9.2
  100 3.8 12.5
  200 5.4 17.7
  400 7.9 25.9
  700 11.1 36.4
  900 12.8 42.0
  1000 13.9 45.6
Specifications
Part # Conductor
(Type, DCR)
Dielectric Type
Nominal O.D
V. P.
Shield Type
Coverage
Nominal D.C.R.
Jacket
(Type, Thickness)
Jacket O.D. Nominal
Capacitance
pF/ft.   pF/m
Weight
Per MFT (lbs)
  I20158TT9 20 AWG
19/32 TC
8.8 Ω/MFT
28.9 Ω/km
Gas Injected Foam PE
.114"
82%
95% TC Braid
4.1 Ω/MFT
13.5 Ω/km
PVC, .030" .195" 28.5 93.5 27
Attenuation
Frequency
MHz
Nominal Attenuation
(dB/100ft)
Nominal Attenuation
(dB/100m)
Black Line
  1 0.4 1.3
  10 1.3 4.3
  50 3.1 10.2
  100 4.5 14.8
  200 6.6 21.7
  400 10.0 32.8
  700 14.2 46.6
  900 16.6 54.5
  1000 18.1 59.4
Specifications
Part # Conductor
(Type, DCR)
Dielectric Type
Nominal O.D
V. P.
Shield Type
Coverage
Nominal D.C.R.
Jacket
(Type, Thickness)
Jacket O.D. Nominal
Capacitance
pF/ft.   pF/m
Weight
Per MFT (lbs)
  I201158BB8 20 AWG
Solid BC
10.3 Ω/MFT
33.8 Ω/km
Solid PE
.116"
66%
80% BC Braid
5.6 Ω/MFT
18.4 Ω/km
PVC, .030" .195" 28.5 93.5 27
Attenuation
Frequency
MHz
Nominal Attenuation
(dB/100ft)
Nominal Attenuation
(dB/100m)
Black Line
  1 0.4 1.3
  10 1.2 3.9
  50 2.9 9.5
  100 4.2 13.8
  200 6.0 19.7
  400 9.1 29.9
  700 12.8 42.0
  900 15.5 50.9
  1000 16.5 54.1
Specifications
Part # Conductor
(Type, DCR)
Dielectric Type
Nominal O.D
V. P.
Shield Type
Coverage
Nominal D.C.R.
Jacket
(Type, Thickness)
Jacket O.D. Nominal
Capacitance
pF/ft.   pF/m
Weight
Per MFT (lbs)
  I20158BT9 20 AWG
Solid BC
10.3 Ω/MFT
33.8 Ω/km
Gas Injected Foam PE
.116"
82%
95% TC Braid
4.1 Ω/MFT
13.5 Ω/km
PVC, .030 .195" 26.0 85.3 25
Attenuation
Frequency
MHz
Nominal Attenuation
(dB/100ft)
Nominal Attenuation
(dB/100m)
Black Line
  1 0.4 1.3
  10 1.1 3.6
  50 2.5 8.2
  100 3.8 12.5
  200 5.6 18.4
  400 8.5 27.9
  700 11.7 38.4
  900 13.7 44.9
  1000 14.5 47.6
Additional Notes:
  Other Jacket Colors Available - 25,000 ft. Minimum Order Required

While every effort is made to insure the product specifications on this web site and all other collateral (i.e. catalogs, printed materials) are current, they are subject to change without notification.
Black Line
Black Line Footer bullet
Distributor Appointment Form Find a Distributor Specials & Promotions Featured Product Contact Isotec, Inc. Sitemap Legal Disclaimers and Copyright Information