| Part Number | Conductor (Type, DCR) |
Dielectric Type Nominal O.D. V.P. |
Shield Type Coverage Nominal D.C.R. |
Jacket (Type, Thickness) |
Jacket O.D. | Nominal Capacitance |
Weight (lbs) Per Mft. |
|
|---|---|---|---|---|---|---|---|---|
| pF/ft | pF/m | |||||||
| IP141CV6 | 14 AWG Solid CCS 12.0 Ω/MFT 39.4 Ω/km |
Gas Injected Foam FEP .274" 83% |
AL Bonded Foil 60% AL Braid 6.9 Ω/MFT 22.6 Ω/km |
Plenum PVDF .020" |
.350" | 16.2 | 53.1 | 66 |
| IP142CV6 | (2) 14 AWG Solid CCS 12.0 Ω/MFT 39.4 Ω/km |
Gas Injected Foam FEP .274" 83% |
AL Bonded Foil 60% AL Braid 6.9 Ω/MFT 22.6 Ω/km |
Plenum PVDF .020" |
.350" x .722" | 16.2 |
53.1 | 150 |
| Frequency MHz |
Nominal Attenuation (dB/100ft) |
Nominal Attenuation (dB/100m) |
|---|---|---|
| 1 | 0.18 | 0.59 |
| 10 | 0.37 | 3.79 |
| 50 | 1.16 | 5.17 |
| 100 | 1.67 | 5.46 |
| 200 | 2.43 | 7.95 |
| 400 | 3.44 | 11.25 |
| 700 | 4.55 | 14.88 |
| 900 | 5.27 | 17.23 |
| 1000 | 5.58 | 18.25 |
Additional Notes:
Other Jacket Colors Available - 25,000 ft. Minimum Order Required

While every effort is made to insure that the product specifications are current and accurate, they are subject to change without notification. Please contact Isotec for specification verification if required.