| Part Number | Conductor (Type, DCR) |
Dielectric Type Nominal O.D. V.P. |
Shield Type Coverage Nominal D.C.R. |
Jacket (Type, Thickness) |
Jacket O.D. | Nominal Capacitance |
Weight (lbs) Per Mft. |
|
|---|---|---|---|---|---|---|---|---|
| pF/ft | pF/m | |||||||
| IP181V6 | 18 AWG Solid BC 6.4 Ω/MFT 21.0 Ω/km |
Gas Injected Foam FEP .170" 83% |
AL Foil 60% AL Braid 9.0 Ω/MFT 29.5 Ω/km |
Plenum PVC .020" |
.244" | 16.2 | 53.1 | 32 |
| IP181V9 w/ 17 AWG CCS Ground |
18 AWG Solid BC 6.4 Ω/MFT 21.0 Ω/km |
Gas Injected Foam FEP .170" 83% |
AL Foil 90% AL Braid 9.7 Ω/MFT 31.8 Ω/km |
Plenum PVDF .020" |
.244" | 16.2 | 53.1 | 39 |
| IP181VQ6 | 18 AWG Solid BC 6.4 Ω/MFT 21.0 Ω/km |
Gas Injected Foam FEP .170" 83% |
AL Foil 60% AL Braid AL Foil 40% AL Braid 4.0 Ω/MFT 3.1 Ω/km |
Plenum PVC .020" |
.244" | 16.2 | 53.1 | 41 |
| Frequency MHz |
Nominal Attenuation (dB/100ft) |
Nominal Attenuation (dB/100m) |
|---|---|---|
| 5 | 0.45 | 1.47 |
| 55 | 1.58 | 5.17 |
| 100 | 1.98 | 6.47 |
| 400 | 4.47 | 14.62 |
| 700 | 5.96 | 19.49 |
| 1000 | 7.97 | 26.06 |
| 1450 | 10.27 | 33.58 |
| 2000 | 12.60 | 41.20 |
Additional Notes:
Other Jacket Colors Available - 25,000 ft. Minimum Order Required
Also Available for Outdoor/Direct Burial Applications

While every effort is made to insure that the product specifications are current and accurate, they are subject to change without notification. Please contact Isotec for specification verification if required.