Sound and Security

CCTV

RG-59

RG-59
Approvals:


Applications:


Temperature:

Conductor:

Insulation:

Shield:

Jacket:
UL Type CMG, CMR, or CMP
NEC Type CCTV/CCTVR

75Ω Closed Circuit TV (CCTV) for Security Applications

-20°C to 75°C

Annealed Bare Copper

Gas Injected Foam PE or FEP

Bare Copper Braid

Riser Rated Black PVC, Plenum (PL-PVC), or PE
for Outdoor non(UL)

 

Cross Section

Specifications
Part Number Conductor
(Type, DCR)
Dielectric Type
Nominal O.D
V. P.
Shield Type
Coverage
Nominal D.C.R.
Jacket
(Type, Thickness)
Jacket O.D. Nominal Capacitance
Weight (lbs)
Per Mft.
pF/ft pF/m
IR201V59 20 AWG
Solid BC
10.2 Ω/MFT
32.8 Ω/km
Gas Injected Foam PE
.144"
83%
95% BC Braid
2.6 Ω/MFT
8.6 Ωkm
Riser Rated PVC
.032"
.242" 16.2 53.1 36
I201V59 Non-riser Rated Version with Identical Electrical Characteristics
Attenuation
Frequency
MHz
Nominal Attenuation
(dB/100ft)
Nominal Attenuation
(dB/100m)
1 .23 0.75
10 .78 2.55
50 1.79 5.86
100 2.56 8.40
200 3.70 12.15
400 5.34 17.52
700 7.10 23.29
900 8.01 26.27
1000 8.51 27.91
Specifications
Part Number Conductor
(Type, DCR)
Dielectric Type
Nominal O.D
V. P.
Shield Type
Coverage
Nominal D.C.R.
Jacket
(Type, Thickness)
Jacket O.D. Nominal Capacitance
Weight (lbs)
Per Mft.
pF/ft pF/m
IP201V59 20 AWG
Solid BC
10.1 Ω/MFT
21.0 Ω/km
Gas Injected Foam FEP
.138"
83%
95% BC Braid
2.6 Ω/MFT
8.5 Ω/km
PL-PVC
.020"
.193" 16.2 53.1 36
Attenuation
Frequency
MHz
Nominal Attenuation
(dB/100ft)
Nominal Attenuation
(dB/100m)
1 0.33 1.08
5 0.52 1.70
10 0.83 2.71
50 1.86 6.07
100 2.65 8.65
400 5.47 17.85
750 7.86 25.65
1000 9.54 31.13
Specifications
Part Number Conductor
(Type, DCR)
Dielectric Type
Nominal O.D
V. P.
Shield Type
Coverage
Nominal D.C.R.
Jacket
(Type, Thickness)
Jacket O.D. Nominal Capacitance
Weight (lbs)
Per Mft.
pF/ft pF/m
I201V59D
Outdoor
Non (UL)
20 AWG
Solid BC
10.2 Ω/MFT
32.8 Ω/km
Gas Injected Foam PE
.144"
83%
95% BC Braid
2.6 Ω/MFT
8.5 Ω/km
PE
w/ Floodant Tape
.025"
.242" 16.3 53.5 30
Attenuation
Frequency
MHz
Nominal Attenuation
(dB/100ft)
Nominal Attenuation
(dB/100m)
1 0.23 0.75
10 0.78 2.55
50 1.79 5.86
100 2.56 8.40
200 3.70 12.15
400 5.34 17.52
700 7.10 23.29
900 8.01 26.27
1000 8.51 27.91
Specifications
Part Number Conductor
(Type, DCR)
Dielectric Type
Nominal O.D
V. P.
Shield Type
Coverage
Nominal D.C.R.
Jacket
(Type, Thickness)
Jacket O.D. Nominal Capacitance
Weight (lbs)
Per Mft.
pF/ft pF/m
IR201CV59 20 AWG
Solid CCS
46.01 Ω/MFT
51.03 Ω/km
Gas Injected Foam PE
.144"
83%
95% BC Braid
2.6 Ω/MFT
8.5 Ω/km
PVC Riser
.032"
.242" 16.3 53.5 30
Attenuation
Frequency
MHz
Nominal Attenuation
(dB/100ft)
Nominal Attenuation
(dB/100m)
1 0.23 0.75
10 0.78 2.55
50 1.79 5.86
100 2.56 8.40
200 3.70 12.15
400 5.34 17.52
700 7.10 23.29
900 8.01 26.27
1000 8.51 27.91
Specifications
Part Number Conductor
(Type, DCR)
Dielectric Type
Nominal O.D
V. P.
Shield Type
Coverage
Nominal D.C.R.
Jacket
(Type, Thickness)
Jacket O.D. Nominal Capacitance
Weight (lbs)
Per Mft.
pF/ft pF/m
IR221SV59 22 AWG
19/34 BC
14.3 Ω/MFT
49.9 Ω/km
Gas Injected Foam PE
.144"
83%
95% BC Braid
2.6 Ω/MFT
8.5 Ω/km
PVC
.032"
.242" 16.2 53.1 36
Attenuation
Frequency
MHz
Nominal Attenuation
(dB/100ft)
Nominal Attenuation
(dB/100m)
1 0.30 0.98
3.6 0.57 1.87
10 0.89 2.92
71.5 2.23 7.31
135 3.12 10.23
270 4.49 14.73
360 5.40 17.71
720 8.14 26.70
1000 10.10 33.13

Additional Notes:
Other Jacket Colors Available - 25,000 ft. Minimum Order Required

Go Back to Short Specifications Product Category Go Back to Products Main Page Part Number Index

While every effort is made to insure that the product specifications are current and accurate, they are subject to change without notification. Please contact Isotec for specification verification if required.